PBGA THERMAL RESISTANCE CORRELATION
CONCLUSIONS
The software modeling calculates the worst case thermal
resistance for each die depending on the module design.
The measurements were performed on typical production
devices using the JEDEC thermal measurement method.
The measured values on this device were within 10% for
JA
and 15% for
JB
. The differences in
JT
results were
further apart in percentage, but less than 1°C/W lower than
the modeling and are explained by the short distance and
the small temperature difference between the top of the die
(junction) and the case temperature.
These results, for all three measured thermal resistances,
correlate the modeling calculations and validates the
correctness of the models.