Data Sheets

Andover Data Center

Issue link: https://read.uberflip.com/i/1216191

Contents of this Issue

Navigation

Page 0 of 1

©2020 All rights reserved. Not all products, pricing and services are available in all areas. Pricing and actual speeds may vary. Restrictions may apply. Subject to change without notice. FLOOR SPACE • Approximately 52,000 square feet of raised floor space. • Slab-on-grade (concrete) floor, with remote water detection monitoring. • SSAE 18 SOC 1 standardized. • 19" cabinets - 24" W x 37" D x 84" H, lockable, 19" mounting rails. • 23" cabinets - 30" W x 37" D x 84" H, lockable, 23" mounting rails. • 42" APC Netshelter cabinets. • Cages - locking chain-link cage space in 87, 100, 120 and 150 square feet increments, custom space available for larger applications. POWER • Utility power (kVA): 3 x 2,500 kVA. • Backup UPS capacity (kW): 3,450 (two Eaton Powerware UPS systems: a five, 675 KW module UPS and a four, 250 KW module UPS). • Power generation capacity (kW): 6,000. • DC power available: No. • AC power installed to order. • N+1 redundancy in power systems. • AC power plant with battery and generator backup. • Three 2,500 kVA power feeds f rom the grid with redundant transformers. • Two UPS systems both parallel redundant, double-conversion. • Four 2-megawatt diesel generators, Navisite-owned, UL listed, double-walled for extra security, with a 15,000 gallon above ground fuel tank and skid-mounted belly tanks, each with 3,500-gallon capacity. • Total of 29,000 gallons of diesel fuel on-site and estimated run time of 90 hours without refueling. Generators can be refueled while running. Generators equipped with a double fuel filter with bypass. • Diesel generators enable "wrap- around" capabilities. Running on generators, Navisite can shut down UPSs to perform maintenance, upgrades, etc., without affecting or interrupting data center operations. • Output to the raised floor has six redundant feeds to A, B, C, D, E and F power distribution units (PDUs), two power circuits for each rack, two power strips within the rack and dual power supplies within the servers. • Generators are run under load every week (we have an on-site 'load bank'). • Generators are serviced quarterly. • UPSs are serviced annually. • Batteries tested quarterly. • Select systems are under service contracts. FIRE DETECTION AND CONTROL SYSTEM • Early-warning AnaLASER fire detection system. • Smoke and high-temperature detectors. NAVISITE DATA CENTERS • Andover, MA • Redhill, UK • Santa Clara, CA • Woking, UK DATA CENTER Andover, MA 1-855-739-3227 | webinfo@navisite.com navisite.com | navisite.com/uk

Articles in this issue

Links on this page

view archives of Data Sheets - Andover Data Center