Andover Data Center

Issue link: https://read.uberflip.com/i/1216191

Contents of this Issue

Navigation

Page 0 of 1

FLOOR SPACE • Approximately 52,000 square feet of raised floor space. • Slab-on-grade (concrete) floor, with remote water detection monitoring. • SSAE 18 SOC 1 standardized. • 19" cabinets - 24" W x 37" D x 84" H, lockable, 19" mounting rails. • 23" cabinets - 30" W x 37" D x 84" H, lockable, 23" mounting rails. • 42" APC Netshelter cabinets. • Cages - locking chain-link cage space in 87, 100, 120 and 150 square feet increments, custom space available for larger applications. POWER • Utility power (kVA): 3 x 2,500 kVA. • Backup UPS capacity (kW): 3,450 (two Eaton Powerware UPS systems: a five, 675 KW module UPS and a four, 250 KW module UPS). • Power generation capacity (kW): 6,000. • DC power available: No. • AC power installed to order. • N+1 redundancy in power systems. • AC power plant with battery and generator backup. • Three 2,500 kVA power feeds f rom the grid with redundant transformers. • Two UPS systems both parallel redundant, double-conversion. • Four 2-megawatt diesel generators, Navisite-owned, UL listed, double-walled for extra security, with a 15,000 gallon above ground fuel tank and skid-mounted belly tanks, each with 3,500-gallon capacity. • Total of 29,000 gallons of diesel fuel on-site and estimated run time of 90 hours without refueling. Generators can be refueled while running. Generators equipped with a double fuel filter with bypass. • Diesel generators enable "wrap- around" capabilities. Running on generators, Navisite can shut down UPSs to perform maintenance, upgrades, etc., without affecting or interrupting data center operations. • Output to the raised floor has six redundant feeds to A, B, C, D, E and F power distribution units (PDUs), two power circuits for each rack, two power strips within the rack and dual power supplies within the servers. • Generators are run under load every week (we have an on-site 'load bank'). • Generators are serviced quarterly. • UPSs are serviced annually. • Batteries tested quarterly. • Select systems are under service contracts. FIRE DETECTION AND CONTROL SYSTEM • Early-warning AnaLASER fire detection system. • Smoke and high-temperature detectors. NAVISITE DATA CENTERS • Andover, MA • Redhill, UK • Santa Clara, CA • Woking, UK DATA CENTER Andover, MA 1-855-739-3227 | hello@navisite.com navisite.com

Articles in this issue

Links on this page

view archives of Data Sheets - Andover Data Center