Use Case

Zenner IoT Solutions & Klax

Issue link: https://read.uberflip.com/i/1422887

Contents of this Issue

Navigation

Page 0 of 0

IR-Head Metering Highlights • Compact and easy to mount • LoRaWAN® Class A • IR-Interface • Lithium Battery (replaceable) • Intervall configurability • Plug`n & Play solution with IoT platform • Tested with other LoRaWAN network servers Interfaces / Sensors • IR-Interface Protocol IEC 62056-21 B & C Protocol SML 1.04 Protocol Logarex • LoRaWAN V1.0.x • Optical Feedback Power supply • 1 x AA Battery Lithium 3 Volt Norm & Safety • EN 62368-1 Mechanics • Housing: ABS • Magnetic mounting • Dimensions (L x B x H) 96 x 35 x 40mm Environment • Protection class IP20 • Operating temperature 0°C to +60°C • Storage temperatur -40°C to 85°C • Rel. humidity 0% bis 95% (not condensing) Estimated battery life in years The battery life of a Lithum AA battery with 1500 mAh at 25 degrees operating temperature, unconfirmed messages, 40 bytes payload and a spreading factor of 9 = 30,000 packets (1 packet contains 4 measurement times) with 15min interval, corresponds to 3 1/2 years battery life (for longer interval periods a battery life of more than 10 years is possible). Information on compatible measuring instruments and further setting options can be found at: https://iot-shop.de/produkt/klax. The values were calculated. Self-discharge and battery life have not been taken into account. Alpha‑Omega Technology GmbH & Co. KG Aschengasse 3 37308 Schimberg / Deutschland Tel: +49 36082 84789-8 Fax: +49 36082 84789-9 Web: www.iot-shop.de Mail: info@iot-shop.de

Articles in this issue

Links on this page

view archives of Use Case - Zenner IoT Solutions & Klax