QUICK REFERENCE GUIDE
mrcy.com
Servers Rugged Level 1
Badger E/F, Badger I/J
SPECIFICATION SERVERS RUGGED LEVEL 1 (RL1) STANDARD REFERENCED
TEMPERATURE
Operating (Sea Level) * 0°C to +50°C MIL-STD-810H, Methods 501.7 & 502.7, Procedure II
Non-Operating (Storage) -40°C to +71°C MIL-STD-810H, Methods 501.7 & 502.7, Procedure I
HUMIDITY
Operating 5% - 95%, non-condensing
MIL-STD-810H, Method 507.6 tailored
Storage 5% - 95%, non-condensing
ALTITUDE
Operating ** 0 ft - 12,500 ft MIL-STD-810H, Method 500.6, Procedure II
Storage 0 ft - 40,000 ft MIL-STD-810H, Method 500.6, Procedure I
VIBRATION & SHOCK
Non-Op Random
(Wheeled Vehicle and Airborne
Transportation)
4.67 Grms Vertical
4.5 Grms Transverse/Longitudinal
MIL-STD-810H Method 514.8, Procedure
Composite profile of:
Category 4 Composite Wheeled Vehicle
(Table 514.8C-VII/Figure 514.8C-6)
& Category 7 C-17 Jet
(Table 514.8C-IX/Figure 514.8C-9)
5 Hz - 2000 Hz
1 hr / axis
Op Vibration
4 Hz - 33 Hz
MIL-STD-167-1A, Type 1
Sinusoidal Sweep & Dwell
Op Shock
X, Y, Z-axes: 20 g
MIL-STD-810H, Method 516.8, Procedure I 11 ms, 1/2-sine pulse
(3 positive, 3 negative)
EMI / EMC
MIL-STD-461G, CE102 CE102
MIL-STD-461G, RE102
RE102
Figure RE102-1, Navy Below Deck
*Product performance may be diminished to achieve extended operating temperatures. Examples include processor throttling, reduced core counts, Turbo-mode disabled, reduced FPGA functionality and/or other limitations.
**Inlet air temperature derating with altitude may be required
6604.00E-1121-qrg-ServersRuggedLevel1