CHANGE REQUEST LoRaWAN Backend Interfaces Version 1.0 CR rev CR Title: Fix the length of NwkId for Type 3 and Type 4 NetIDs Submitter: Name: Alper Yegin Contact Email: alper.yegin@actility.com Contact Other: Affiliation: Actility Work Item Ref: Date: May 22, 2017 Category: F Use one of the following categories: F (correction) A (corresponds to a correction in an earlier release) B (addition of feature) C (functional modification of feature) D (editorial modification / clarification) Reason for change: It was discovered that the NetID allocation spreadsheet has been out of synch with the Backend Interfaces specification with respect to the length of NwkId for Type 3 and Type 4 NetIDs. The two needed to be aligned. Since a number of networks have already been deployed according to the details in the spreadsheet, it was decided to synch the Backend spec with the spreadsheet. Summary of change: Adjust the NwkID length for Type 3 and Type 4 NetIDs in the spec according to the allocation spreadsheet (https://members.lora- alliance.org/higherlogic/ws/groups/technical/documents/network262/document?docu ment_id=3303). Clauses affected: