LoRaWAN 1.1 Regional Parameters
©2017 LoRa Alliance™ Page 54 of 56
The authors reserve the right to change
specifications without notice.
The class B default downlink pingSlot frequency is 866.550MHz 1392
1393
2.9.9 INDIA 865-867 Default Settings 1394
The following parameters are recommended values for the INDIA 865-867MHz band. 1395
1396
RECEIVE_DELAY1 1 s 1397
RECEIVE_DELAY2 2 s (must be RECEIVE_DELAY1 + 1s) 1398
JOIN_ACCEPT_DELAY1 5 s 1399
JOIN_ACCEPT_DELAY2 6 s 1400
MAX_FCNT_GAP 16384 1401
ADR_ACK_LIMIT 64 1402
ADR_ACK_DELAY 32 1403
ACK_TIMEOUT 2 +/- 1 s (random delay between 1 and 3 seconds) 1404
If the actual parameter values implemented in the end-device are different from those default 1405
values (for example the end-device uses a longer RECEIVE_DELAY1 and 1406
RECEIVE_DELAY2 latency), those parameters must be communicated to the network 1407
server using an out-of-band channel during the end-device commissioning process. The 1408
network server may not accept parameters different from those default values. 1409
1410
1411