LoRa Alliance
5177 Brandin Court,
Fremont, CA 94538 USA
LoRaWAN 1.0.4 End Device Certification Page 143 of 173
Requirements for All Regions Version 1.4
Copyright © 2021 LoRa Alliance, Inc. All rights reserved. www.lora-alliance.org
Step Procedure Frame Sequence Test
Purpose
End Device
- TCL
Frame
4 DUT sends Unconfirmed frame
→
DUT
discards the
oversized
frame and
sends
Unconfirmed
frame
The TCL sends Unconfirmed frame
on RX2 window
CP-CMD TxFramesCtrlReq
FPort = 224
FrameType = Confirmed
Payload (i) = [0x]0702
(MaxLen + 1 for UL DR-Y)
5 DUT sends Unconfirmed frame
→
DUT
continues
normal
operation
The TCL sends Confirmed frame on
RX1 window
CP-CMD TxFramesCtrlReq
FPort = 224
FrameType = No change
Payload (i) = [0x]0700
(MaxLen + 1 for UL DR-X)
6 DUT sends Unconfirmed frame
→
No ACK DUT
continues
normal
operation
(RX1)
The TCL sends Confirmed frame on
RX2 window
CP-CMD TxFramesCtrlReq
FPort = 224
FrameType = No change
Payload (i) = [0x]0700
(MaxLen + 1 for UL DR-Y)
7 DUT sends Unconfirmed frame
→
No ACK DUT
continues
normal
operation
(RX2)
Repeat above steps 2-7 until all Data
Rates in the Max Payload table are
tested
8 DUT sends Unconfirmed frame
→