Copyright © 2021 LoRa Alliance, Inc. All rights reserved. www.lora-alliance.org
achieved, the TCL sends a downlink whose payload is one byte greater than the scenario's 1194
maximum. Note the payload content is random (i.e. not the echo command). 1195
The TCL must use both confirmed and unconfirmed oversized frames; as well as target both 1196
receive windows. 1197
Verify 1198
• The DUT continues normal operation in the presence of oversized downlinks. DUT 1199
must silently discard the oversized downlinks. 1200
2.5.11.d.i. Test Procedure Frame Sequence Chart 1201
1202