ENVIRONMENTAL PROTECTIONS FOR THE TACTICAL EDGE
Rugged Packaging and Cooling Technologies
mrcy.com
ENVIRONMENTAL QUALIFICATION LEVELS — OPENVPX — MULTIFUNCTION PROCESSING
AIR COOLED
CONDUCTION
COOLED
AIR FLOW-
BY
AIR FLOW-
THROUGH
LIQUID
FLOW-
THROUGH
LIQUID
FLOW-BY
COMMERCIAL
RL0
RUGGED RL1 RUGGED RL2 RUGGED RL3
RUGGED
RL4
RUGGED RL5 RUGGED RL6 RUGGED RL7
3U cooling typical power ~100W* ~40W / ~100W** ~150W* Contact factory
6U cooling typical power ~150W* ~130W* ~100W* ~140W** ~200W* 300W***
Temperature
Operating 0 °C to +40 °C -25 °C to +50 °C -40 °C to +55 °C -40 °C to +70 °C -40 °C to +55 °C
-40 °C up to +71 °C air temp
-40 °C to +50 °C fluid Inlet (PAO)
-40 °C to +60 °C fluid Inlet (EGW)
Extended¹ 0 °C to +50 °C N/A 40 °C to +70 °C 40 °C to +85 °C 40 °C to +71 °C
Storage³ -40 °C to +85 °C -55 °C to +85 °C -55 °C to +105 °C
Max rate of
change
N/A 5 °C/min 10 °C/min
COTS/COTS+
Durability:
temperature
range
N/A 250 cycles, -50 °C to +100 °C
MOTS/MOTS+ N/A 500 cycles, -50 °C to +100 °C
MOTS+ Ultra N/A 625 cycles, -50 °C to +100 °C
COTS/COTS+
MOTS/MOTS+
MOTS+ Ultra
Durability:
dwell @
extremes
N/A 30 min. after stabilization
COTS/COTS+
MOTS/MOTS+
MOTS+ Ultra
Durability:
max rate of
change
N/A 4 °C/min ± 2 °C/min
Humidity
Operating²
10-90%, non-con-
densing
5-95% ± 4%, non-condensing
Storage
Altitude
Operating² 0-10,000 ft 0-30,000 ft 0-60,000 ft 0-30,000 ft 0-70,000 ft
Storage 0-30,000 ft 0-50,000 ft 0-70,000 ft
Vibration
Random
0.04 g2/Hz peak;
5-100 Hz, 1 hr/axis
0.04 g2/Hz peak; 20-2000 Hz, 1
hr/axis
0.005 to 0.100 g2/Hz incline from 5 to 100 Hz, 0.100 g2/Hz constant from 100 to 1000 Hz, 0.100
to 0.025 g2/Hz decline from 1000 to 2000 Hz; 1 hr/axis
Sine N/A .75" displacement 5 to 15 Hz; 10G peak from 15 to 2000 Hz; 1 hr/axis
Shock
z-axis: 20g;
X, Y-axes: 32g;
11 ms 1/2-sine pulse,
(3 pos., 3 neg.)
z-axis: 50g;
X, Y-axes: 80g;
11 ms 1/2-sine pulse,
(3 positive, 3 negative)
Salt/Fog N/A Contact factory 5% NaCl
VITA 47
EAC1: low op temp
EAC1: AC1C2C1V1OS1
EAC4:
AC1C2C2V2OS1
EAC5:
AC2C2C2V2OS1
EAC3:
AC3C3C4V2OS1
ECC3:
CC3C3C4V3OS2
ECC4:
CC4C4C4V3OS2
EFC2: FC2C2C4V3OS2
EFC3: FC3C2C4V3OS2
ELC2: LC2C2C4V3OS2 (PAO)
ELC3: LC3C2C4V3OS2 (EGW)
¹ Product performance may be diminished to achieve extended operating temperatures.
Examples include processor throttling, reduced core counts, reduced FPGA functionality
and/or other limitations.
² The test is a non-operational test with operational testing occurring during the last
2 hours of each full cycle (2 cycles total) per MIL-STD-810.
³ Storage temperature is a non-operational test defined per MIL-STD-810, where the product
is brought to the high storage temperature for a minimum of two hours, returned to ambient
temperature and functionally tested. The product is then brought to the low storage temperature
for a minimum of 2 hours and returned to slightly above ambient for functional testing. All tem-
perature transition rates are less than of 10°C/min. One cold/hot cycle constitutes the complete
non-operational storage temperature test.
* For forced convection cooled product, the end user must maintain required volumetric flow rate
(CFM). Contact Mercury for application specific guidance.
** Module conduction cold-plate edge is maintained at or below 71°C.
*** Performance varies with coolant type, fluid temperature and flow rate. Contact Mercury for
application specific guidance.