3 ENVIRONMENTAL PROTECTIONS FOR THE TACTICAL EDGE Rugged Packaging and Cooling Technologies mrcy.com ENVIRONMENTAL QUALIFICATION LEVELS — OPENVPX — MULTIFUNCTION PROCESSING AIR COOLED CONDUCTION COOLED AIR FLOW- BY AIR FLOW- THROUGH LIQUID FLOW- THROUGH LIQUID FLOW-BY COMMERCIAL RL0 RUGGED RL1 RUGGED RL2 RUGGED RL3 RUGGED RL4 RUGGED RL5 RUGGED RL6 RUGGED RL7 3U cooling typical power ~100W* ~40W / ~100W** ~150W* Contact factory 6U cooling typical power ~150W* ~130W* ~100W* ~140W** ~200W* 300W*** Temperature Operating 0 °C to +40 °C -25 °C to +50 °C -40 °C to +55 °C -40 °C to +70 °C -40 °C to +55 °C -40 °C up to +71 °C air temp -40 °C to +50 °C fluid Inlet (PAO) -40 °C to +60 °C fluid Inlet (EGW) Extended¹ 0 °C to +50 °C N/A 40 °C to +70 °C 40 °C to +85 °C 40 °C to +71 °C Storage³ -40 °C to +85 °C -55 °C to +85 °C -55 °C to +105 °C Max rate of change N/A 5 °C/min 10 °C/min COTS/COTS+ Durability: temperature range N/A 250 cycles, -50 °C to +100 °C MOTS/MOTS+ N/A 500 cycles, -50 °C to +100 °C MOTS+ Ultra N/A 625 cycles, -50 °C to +100 °C COTS/COTS+ MOTS/MOTS+ MOTS+ Ultra Durability: dwell @ extremes N/A 30 min. after stabilization COTS/COTS+ MOTS/MOTS+ MOTS+ Ultra Durability: max rate of change N/A 4 °C/min ± 2 °C/min Humidity Operating² 10-90%, non-con- densing 5-95% ± 4%, non-condensing Storage Altitude Operating² 0-10,000 ft 0-30,000 ft 0-60,000 ft 0-30,000 ft 0-70,000 ft Storage 0-30,000 ft 0-50,000 ft 0-70,000 ft Vibration Random 0.04 g2/Hz peak; 5-100 Hz, 1 hr/axis 0.04 g2/Hz peak; 20-2000 Hz, 1 hr/axis 0.005 to 0.100 g2/Hz incline from 5 to 100 Hz, 0.100 g2/Hz constant from 100 to 1000 Hz, 0.100 to 0.025 g2/Hz decline from 1000 to 2000 Hz; 1 hr/axis Sine N/A .75" displacement 5 to 15 Hz; 10G peak from 15 to 2000 Hz; 1 hr/axis Shock z-axis: 20g; X, Y-axes: 32g; 11 ms 1/2-sine pulse, (3 pos., 3 neg.) z-axis: 50g; X, Y-axes: 80g; 11 ms 1/2-sine pulse, (3 positive, 3 negative) Salt/Fog N/A Contact factory 5% NaCl VITA 47 EAC1: low op temp EAC1: AC1C2C1V1OS1 EAC4: AC1C2C2V2OS1 EAC5: AC2C2C2V2OS1 EAC3: AC3C3C4V2OS1 ECC3: CC3C3C4V3OS2 ECC4: CC4C4C4V3OS2 EFC2: FC2C2C4V3OS2 EFC3: FC3C2C4V3OS2 ELC2: LC2C2C4V3OS2 (PAO) ELC3: LC3C2C4V3OS2 (EGW) ¹ Product performance may be diminished to achieve extended operating temperatures. Examples include processor throttling, reduced core counts, reduced FPGA functionality and/or other limitations. ² The test is a non-operational test with operational testing occurring during the last 2 hours of each full cycle (2 cycles total) per MIL-STD-810. ³ Storage temperature is a non-operational test defined per MIL-STD-810, where the product is brought to the high storage temperature for a minimum of two hours, returned to ambient temperature and functionally tested. The product is then brought to the low storage temperature for a minimum of 2 hours and returned to slightly above ambient for functional testing. All tem- perature transition rates are less than of 10°C/min. One cold/hot cycle constitutes the complete non-operational storage temperature test. * For forced convection cooled product, the end user must maintain required volumetric flow rate (CFM). Contact Mercury for application specific guidance. ** Module conduction cold-plate edge is maintained at or below 71°C. *** Performance varies with coolant type, fluid temperature and flow rate. Contact Mercury for application specific guidance.

Articles in this issue

Links on this page

view archives of Product References - Tech Brief: Environmental Protections for Operations at the Edge