LoRaWAN ® Certification Protocol Specification TS009-1.1.0 ©2023 LoRa Alliance ® Page 20 of 26 The authors reserve the right to change specifications without notice. The TCL can verify the correct operation of the RxAppCntRstReq command by issuing an 457 RxAppCntReq command. 458 5.11 Link Check Request MAC Command (LinkCheckReq) 459 460 The LinkCheckReq command has no payload. 461 462 This command instructs the DUT to send a LinkCheckReq MAC command. 463 5.12 DeviceTimeReq MAC Command (DeviceTimeReq) 464 465 The DeviceTimeReq command has no payload. 466 467 This command instructs the DUT to send a DeviceTimeReq MAC command. 468 5.13 PingSlotInfoReq MAC Command (PingSlotInfoReq) 469 470 Note: This command is required for only Class B DUTs. 471 472 The PingSlotInfoReq command payload is used to convey the ping slot periodicity. 473 474 This command instructs the DUT on the ping slots periodicity to be used when the DUT 475 decides to send a PingSlotInfoReq MAC command. 476 477 Size (octets) 1 Field Periodicity Table 13: PingSlotInfoReq 478 The Periodicity field follows the same rules as the ones provided by [TS001]. 479 480