Document

TS009-1.2.1 Certification Protocol

Issue link: https://read.uberflip.com/i/1527095

Contents of this Issue

Navigation

Page 17 of 26

LoRaWAN ® Certification Protocol Specification TS009-1.2.1 ©2024 LoRa Alliance ® Page 18 of 27 The authors reserve the right to change specifications without notice. 5.8 Uplink Frames Control Command (TxFramesCtrlReq) 404 405 The TxFramesCtrlReq command is used to change the frame type to be used by subsequent 406 uplink frames. This command MAY also convey N extra octets. 407 408 Size (octets) 1 N-1 Field FrameType 0..N Table 9: TxFramesCtrlReq 409 The FrameType field encodes the frame type to be used by the DUT on all subsequent uplink 410 frames. 411 412 FrameType Description Remarks 0 No change Allows the TCL to perform a no-operation downlink 1 Unconfirmed L2 Unconfirmed FType = 2 frames 2 Confirmed L2 Confirmed FType = 4 frames 3-255 RFU Table 10: FrameType values description 413 The TCL can verify the correct operation by checking that the FType of the MHDR field of 414 subsequent uplink frames has changed as requested. 415 416

Articles in this issue

view archives of Document - TS009-1.2.1 Certification Protocol