TR016-1.0.0 LoRaWAN Relay Technical Recommendations

Issue link: https://read.uberflip.com/i/1546053

Contents of this Issue

Navigation

Page 15 of 19

LoRaWAN ® Relay Technical Recommendations TR016-1.0.0 ©2026 LoRa Alliance ® Page 16 of 20 The authors reserve the right to change specifications without notice. may be lost over the air. To achieve this, the network server MAY use one of the following 348 techniques: 349 1. Either use a more conservative level than the effective downlink transmission frequency. 350 For example, if the network server expects 1 downlink frame every 8 uplink frames, it might 351 set SmartEnableLevel to 1 (encoding a value of 16) instead of 0 (encoding a value 352 of 8) to leave margin for downlink packet loss. 353 2. Or use Confirmed-Data-Downlink frame type to ensure reliable downlink delivery. 354