Chapter 6
135
How it works...
Manually removing a node from our OpenStack Storage cluster is done in three steps:
1. Setting the node's weight to be 0, so data isn't being replicated to it, by using the
swift-ring-builder set_weight command.
2. Rebalancing the rings to update the data replication.
3. Removing the node from the OpenStack Storage cluster, using the
swift-ring-builder remove command.
Once done, we are then free to decommission that node. We repeat this for each node
(or device) in the zone.
Detecting and replacing failed hard drives
OpenStack Storage won't be of much use if it can't access the hard drives where our data is
stored; so being able to detect and replace failed hard drives is essential.
Getting ready
Log in to an OpenStack Storage node as well as the proxy server.
How to do it...
To detect a failing hard drive, carry out the following:
Storage node
1. We first need to configure a cron job that monitors /var/log/kern.log for failed
disk errors on our storage nodes. To do this, we create a configuration file named /
etc/swift/swift-drive-audit.conf,
as follows:
[drive-audit]
log_facility=LOG_LOCAL0
log_level=INFO
device_dir=/srv/node
minutes=60
error_limit=1
2. We then add a cron job that executes swift-drive-audit hourly, as follows:
echo '/usr/bin/swift-drive-audit /etc/swift/swift-drive-audit.
conf' | sudo tee -a /etc/cron.hourly/swift-drive-audit
www.it-ebooks.info