Issue link: https://read.uberflip.com/i/1494345
LoRaWAN ® Certification Protocol Specification TS009-1.1.0 ©2023 LoRa Alliance ® Page 21 of 26 The authors reserve the right to change specifications without notice. 5.14 Class B Beacon Status Indication Control Command 481 (BeaconRxStatusIndCtrl) 482 483 The BeaconRxStatusIndCtrl command requests the DUT to activate/deactivate the 484 BeaconRxStatusInd transmission. 485 486 Size (octets) 1 Field CTRL Table 14: BeaconRxStatusIndReq 487 The CTRL field encodes the BeaconRxStatusInd transmission state. A value of 1 means the 488 transmission is activated and a value of 0 means the transmission is deactivated. 489 490 The TCL can verify the correct operation by checking BeaconRxStatusInd transmission. 491 5.15 Class B Beacon Status Indication Command (BeaconRxStatusInd) 492 493 The BeaconRxStatusInd command is autonomously sent by the DUT every time a beacon 494 is supposed to be received. 495 496 Size (octets) 1 2 3 1 2 1 1 4 7 Fields State RxCnt Frequency DR RSSI SNR Param Time GwSpecific Table 15: BeaconRxStatusInd 497 The State field encodes the beacon acquisition state. A value of 1 means that the beacon 498 acquisition is ON and a value of 0 means that the beacon acquisition is OFF. 499 500 The RxCnt field corresponds to the current BeaconCnt value. 501 502 The Frequency field is a 24-bit unsigned integer. The actual channel frequency in Hz is 503 100 x Frequency, whereby values representing frequencies below 100 MHz are reserved for 504 future use. 505 506 The DR field is the data rate index. 507 508 The RSSI field is a signed 16-bit value expressed in dBm of the received beacon signal 509 strength. 510 511 The SNR field is a signed 8-bit value expressed in dB of the received beacon signal to noise 512 ratio. 513 514 The Param field follows the same rules as the ones provided by [TS001]. 515 516 The Time field follows the same rules as the ones provided by [TS001]. 517 518 The GwSpecific field follows the same rules as the ones provided by the [TS001]. 519
